Adapting Coming Home Time







Adapting Coming Home Time

Coming Home function: Duration of illumination time when leaving the vehicle.

Illumination time of Coming Home function can be set variably between 0 and 120 seconds.

- Connect the Vehicle Diagnostic Tester. Testing and Inspection

- On the Vehicle Diagnostic Tester, select "Guided Fault Finding".

- Using the "GO TO" button, select "Functions/Component selection" and the following menu options in sequence:

• Body

• Electrical Equipment

• 01 - On Board Diagnostic (OBD) capable systems

• Vehicle electrical system control module

• Functions of Vehicle Electrical System Control Module

• Adapting Coming Home Time