Door Control Switch: Inspection
- INSPECT POWER WINDOW MASTER SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFIED CONDITIONTester Connection Switch Condition Specified Condition 1 (E) - 2 (L) Lock Below 1 Ω 1 (E) - 2 (L) 1 (E) - 9 (UL) OFF (Free) 10 kΩ or higher 1 (E) - 9 (UL) Unlock Below 1 Ω If the result is not specified, replace power window master switch.
- Measure the resistance according to the value(s) in the table below.
- INSPECT DOOR CONTROL SWITCH ASSEMBLY (for Front Passenger Side)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFIED CONDITIONTester Connection Switch Condition Specified Condition 3 (E) - 4 (L) Lock Below 1 Ω 3 (E) - 4 (L)
2 (UL) - 3 (E)OFF (Free) 10 kΩ or higher 2 (UL) - 3 (E) Unlock Below 1 Ω If the result is not specified, replace door control switch.
- Measure the resistance according to the value(s) in the table below.