Pick-Up Coil Resistance
Note pick-up coil terminal identification on the distributor. See Fig 1-10. Using ohmmeter, measure resistance between specified terminals. See PICK-UP COIL RESISTANCE SPECIFICATIONS table. Replace distributor assembly if pick-up coil resistance is not within specification.
PICK-UP COIL RESISTANCE SPECIFICATIONS
| Application | Pick-Up Coil Terminals | (1) Ohms | ||
|---|---|---|---|---|
| 1.8L (7A-FE) | G+ & G- | 185-275 | ||
| 1.8L (7A-FE) | NE+ & NE- | 370-550 | ||
| 2.2L (5S-FE) Calif. | G1 & G- | 125-200 | ||
| 2.2L (5S-FE) Calif. | G2 & G- | 125-200 | ||
| 2.2L (5S-FE) Calif. | NE & G- | 155-250 | ||
| 2.2L (5S-FE) Ex. CA | G+ & G- | 185-275 | ||
| 2.2L (5S-FE) Ex. CA | NE+ & NE- | 370-550 | ||
|
||||