PURPOSE
The purpose of this bulletin is to inform Saturn Retailers of changes to the engine ground location. For 2003 Saturn ION vehicles, there are three possible locations for the ECM/TCM/ignition module ground location:
VEHICLES BUILT PRIOR TO VIN 3Z118970
Vehicles built prior to VIN 3Z118970 utilize the lower stud on the intake cam end cover plate. Refer to the Service Procedure in this bulletin for instructions to relocate the ground to the rear cam cover. While it is not necessary to relocate this ground terminal, it is suggested that whenever the intake cam cover stud is being serviced, the ring terminal ground connection be moved to the updated location.
VEHICLES BUILT BETWEEN AND INCLUDING VINS 3Z118970 AND 3Z176922
Vehicles built between and including VINs 3Z118970 and 3Z176922 utilize the ground stud toward the rear of the cam cover.
VEHICLES BUILT AFTER AND INCLUDING VIN 3Z176923
Vehicles built after and including VIN breakpoint 3Z176923 have the ground located at G105. The G105 ground placement is located in the lower left front side of the engine, above the starter. Refer to the following illustration for location.
SERVICE PROCEDURE
REMOVAL
- Remove nut from intake cam end cover plate lower stud.
- Remove ground harness ring terminal and discard nut removed in Step 1. Tighten the end cover stud to 25 N.m (18 ft-lb).
INSTALLATION
- Remove the ground strap retaining stud from the camshaft cover.
- Install the ECM/TCM/ignition module ground harness ring terminal ON TOP of the braided ground strap.
- Install the ground strap retaining stud to the camshaft cover to secure the ground harness ring terminal and braided ground strap. Tighten the ground strap stud to 10 N.m (89 in-lb).