Ignition Coil (2.0L & 2.0L Turbo)
- Disconnect ignition coil connector. Using an ohmmeter, measure primary coil resistance between ignition coil terminals No. 3 and 2. See Fig 1, TEST 1. Also, measure resistance between ignition coil connector terminals No. 3 and 1. Primary resistance should be .70-.86 ohms at 68°F (20°C).
- With ignition coil connector still disconnected, measure secondary coil resistance. Measure resistance between high-voltage terminals for cylinders No. 1 and 4, and between high-voltage terminals for cylinders No. 2 and 3. See Fig 1, TEST 2.
- Secondary resistance should be 11,300-15,300 ohms. Replace ignition coil if it does not test as described.
NOTE: To test power transistors, use an analog ohmmeter.