M/T Models

Power is supplied at all times:

With the ignition switch in the START position, power is supplied:

With the ignition switch in the ON or START position, power is supplied:

When the clutch pedal is depressed, ground is supplied to IPDM E/R terminal 50 through the clutch interlock switch and body grounds E15 and E24.

Provided that the IPDM E/R receives a starter relay request ON signal from the BCM over the CAN lines, the IPDM E/R grounds the starter relay and power is supplied:

The starter motor plunger closes and provides a closed circuit between the battery and the starter motor. The starter motor is grounded to the cylinder block. With power and ground supplied, the starter motor operates. In the event that the CAN communication line fails between the IPDM E/R and the BCM, the IPDM E/R will default to a starter relay request ON signal as long as the ignition switch remains in the START or ON position.