LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2011 >> 6 s Touring Plus >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Security System And Locks System >> Immobilizer System-Related Parts Programming [Keyless Entry System] >> No. 3 Additional Key Programming Procedure Changing >> Procedure

No. 3 Additional Key Programming Procedure Changing: Procedure

DIAGNOSIS PROCEDURE

Step Procedure Action after procedure
1 CHANGE CUSTOMER SPARE KEY PROGRAMMING PROCEDURE 
  1. Connect the M-MDS (IDS) to the DLC-2.

    (See M-MDS CONNECTING PROCEDURE .)

  2. Switch the ignition ON using a key (the key can be either the valid key or an unprogrammed key).
    NOTE:
    • If an unprogrammed key is used, the security light starts flashing and DTC 15 is displayed after approx. 1  min. However, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
  3. After the vehicle is identified, select the following items from the initial screen of the M-MDS.
    • When using the IDS (laptop PC):
    1. Select the "Body"
    2. Select the "Security"
    3. Select the "PATS Functions"
  4. Select either of the following from the M-MDS menu to change the additional key programming procedure.
    • When "Customer Spare Key Programming Enable" is selected: The additional key programming procedure using valid keys is enabled.
    • When "Customer Spare Key Programming Disable" is selected: The additional key programming procedure using valid keys is disabled.
  5. Perform the security access according to the directions on the M-MDS screen.
  6. After verifying that the PATS function menu is displayed again on the M-MDS screen, select "Finish (this menu)".
  7. Switch the ignition to off.
Procedure is completed