LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2000 >> Millenia V6-2.5L DOHC >> Repair and Diagnosis >> Heating and Air Conditioning >> Service and Repair >> Refrigerant System General Procedures

Refrigerant System General Procedures

Charging Procedure Flow:




Charging Procedure Flow




Manifold Gauge Set Installation
1. Fully close the valves of the manifold gauge.
2. Connect charging hoses to the high- and low-pressure side joints of the manifold gauge.
3. Connect quick couplers to the ends of the charging hoses.
4. Remove the caps from the charging valves of cooler pipe No.1 and No.4.
5. Connect the quick couplers to the charging valves of cooler pipe No.1 and No.4.