LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2012 >> Azera V6-3.3L >> Repair and Diagnosis >> Heating and Air Conditioning >> Blower Motor Resistor >> Testing and Inspection

Blower Motor Resistor: Testing and Inspection





Inspection

1. Ignition "ON"
2. Manually operate the control switch and measure the voltage of blower motor.
3. Select the control switch to raise voltage until high speed.










Specification





*AUTO COOLING: Auto speed (4.5V~B+)
*AUTO HEATING: Auto speed (4.5V~11.3V)
4. If the measured voltage is not specification, substitute with a known-good power mosfet and check for proper operation.
5. If the problem is corrected, replace the power mosfet.