LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2011 >> Civic L4-1.8L >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Variable Valve Timing Actuator Position Sensor >> Service and Repair

Variable Valve Timing Actuator Position Sensor: Service and Repair




Rocker Arm Oil Pressure Sensor (EOP Sensor) Removal/Installation

1. Remove the cowl cover and the under-cowl panel Service and Repair.

2. Disconnect the rocker arm oil pressure sensor (EOP sensor) connector (A).





3. Remove the bracket (B) and the rocker arm oil pressure sensor (EOP sensor) (C).

4. Install the parts in the reverse order of removal with a new O-ring (D).