LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 1987 >> Prelude L4-1955cc 2000 >> Repair and Diagnosis >> Heating and Air Conditioning >> Blower Motor Switch >> Service and Repair

Blower Motor Switch: Service and Repair

Fig. 38 A/C control switch replacement.:





1. Remove the right lower dash panel.
1. Remove the radio.
1. Pry the knob off the heater temperature control.
1. Remove screws from the control lever bracket and remove the bracket from the control panel.
1. Remove the screw, and disconnect the A/C wire coupler, then remove the switch Fig. 38.
1. Reverse procedure to install.