LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2007 >> Explorer 2WD V8-4.6L VIN 8 >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Variable Valve Timing Solenoid >> Service and Repair

Variable Valve Timing Solenoid: Service and Repair

VARIABLE CAMSHAFT TIMING (VCT) OIL CONTROL SOLENOID







Removal and Installation
1. Remove the valve cover.
2. Remove the bolt and the VCT oil control solenoid.
- To install, tighten to 5 Nm (44 lb-in).