LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Excursion 2WD V10-6.8L VIN S >> Repair and Diagnosis >> Heating and Air Conditioning >> Coupler HVAC >> Service Precautions

Coupler HVAC: Service Precautions

CAUTION:
^ Use only new green O-rings. The use of any O-ring seals other than specified may result in intermittent leakage during vehicle operation.
^ Do not use metal tools to remove the O-ring seal. They can cause axial scratches across the O-ring groove resulting in refrigerant leaks.
^ Support the female fitting with a wrench to prevent the tubes from twisting.
^ Do not use a screwdriver or similar tool to remove the A/C tube lock coupling spring; this can cause axial scratches across the O-ring grooves resulting in refrigerant leaks.
^ Maintain low speed drill rotation when inserting or removing the cleaning tool to prevent axial scratches which may cause future leaks.