LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1994 >> Taurus V6-232 3.8L >> Repair and Diagnosis >> Powertrain Management >> Emission Control Systems >> Exhaust Gas Recirculation >> Vacuum Check Valve >> Testing and Inspection

Vacuum Check Valve: Testing and Inspection

Vacuum Check Valve:






Apply 54 kPa (16 in Hg) vacuum to "check" side of the valve and trap. If vacuum remains above 50 kPa (15 in Hg) for 10 seconds, the valve is acceptable.