LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1992 >> Aerostar AWD V6-245 4.0L >> Repair and Diagnosis >> Specifications >> Electrical Specifications >> Alternator

Alternator

Ford Make With Integral Regulator
Current Rating
Note: At 15 Volts
Slip Ring Turning - Minimum Diameter Slip Ring Turning - Maximum Runout Brush Length - New Brush Length - Wear Limit
40 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
40 HE Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
60 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
65 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
75 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
80 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)