NOTE: Make sure the old gasket material is completely removed from air injection pipe.

1. Install new gasket (5) and air injection check valve (1) to pipe.
2. Install air injection check valve mounting bolts (4).

NOTE: The quick connect fitting on the air outlet tube is slotted to fit the air injection check valve fitting. Line the slot up when making the connection.

3. Install air pump outlet tube (3) to air injection check valve (1) connection. A click noise will indicate a good connection.