LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 1996 >> Sebring V6-2.5L SOHC 24 Valve >> Repair and Diagnosis >> Powertrain Management >> Ignition System >> Testing and Inspection >> Oscilloscope Patterns and Waveforms >> Measurement Method

Measurement Method

1. Clamp the No. 1 cylinder spark plug cable with the secondary pickup.
2. Clamp the No. 1 cylinder spark plug cable with the trigger pickup.
3. Clamp each spark plug cable with the secondary pickup to check the waveform for each cylinder.