Installation Procedure
- With the help of a second technician, install the drive motor generator power inverter module (1) into position.
- Install the engine wiring harness brackets (2), in the position shown, and tighten the fasteners (1) to 22 N.m (16 lb ft).
- Install the battery negative cable terminal (3), to the generator motor power inverter module case ground, and tighten the fastener (4) to 9 N.m (80 lb in).
- Install the engine wiring harness terminal (2), to the generator motor power inverter module case ground, and tighten the fastener (1) to 9 N.m (80 lb in).
- Install the generator control module coolant hose. Refer to Generator Control Module Coolant Hose Replacement (PE From APM TO TPIM) .
- Install the electric differential drive motor power inverter module cooling hose. Refer to Electric Differential Drive Motor Power Inverter Module Cooling Hose Replacement (PE TPIM to LTR) .
- Connect the transmission fluid pump cable connector (1) and the 2 engine wiring harness connectors (2), to the drive motor generator power inverter module.
- Connect the transmission 3 phase cable (2) to the side of the drive motor generator power inverter module. Tighten the connector fastener (1) to 9 N.m (80 lb in).
- Connect the 300 volt high voltage cable (2) to the drive motor generator power inverter module (3) and tighten the connector fastener (1) to 9 N.m (80 lb in).
- Connect the 300 volt high voltage connector (2), with a NEW seal, to the drive motor generator power inverter module (3). Tighten the connector fastener (1) to 9 N.m (80 lb in).
- Install the high voltage battery disconnect control module. Refer to High Voltage Battery Disconnect Control Module Replacement (with quick charge) High Voltage Battery Disconnect Control Module Replacement (without quick charge) .
- Install the high voltage disconnect circuit cover. Refer to High Voltage Disconnect Circuit Connector Cover Replacement .
- Enable the high voltage system. Refer to High Voltage Enabling .
- For control module programming and setup procedures, refer to Control Module References .
CAUTION:
Refer to Fastener Caution .
NOTE:
Critical high voltage fastener. Perform second torque verification check following re-assembly.
NOTE:
Critical high voltage fastener. Perform second torque verification check following re-assembly.
Fig 4: Engine Wiring Harness Connectors, Connector Handles And Transmission Fluid Pump Cable Connector